Reference tables
Reference tables showing the maximum permissible error for different types of measuring equipment.
Table 1: Standards of mass
Note:
Refer to Schedule 3 of the Weights and Measures Regulations 1999 as amended for the Maximum Permissible Errors for Class M3.
Corrected errors are taken from OIML R111 Table 1
Nominal Value of Standards | For testing Traders’ M1 and class II weighing instruments | Inspectors and Accredited Persons’ Working Standards | Traders’ Weight | Traders’ Weights Accredited Persons' standards > 50 kg | Traders’ Weights |
---|---|---|---|---|---|
|
Class F2 + mg |
Class M1 + mg |
Class M1-2 + mg |
Class M2 + mg |
Class M2-3+ mg |
1000 kg |
|
50 000 |
100 000 |
160 000 |
300 000 |
500 kg |
|
25 000 |
50 000 |
80 000 |
160 000 |
200 kg |
|
10 000 |
20 000 |
30 000 |
60 000 |
100 kg |
|
5 000 |
10 000 |
16 000 |
30 000 |
50 kg |
800 |
2500 |
5 000 |
8 000 |
16 000 |
20 kg |
300 |
1000 |
|
3000 |
|
10 kg |
160 |
500 |
|
1600 |
|
5 kg |
80 |
250 |
|
800 |
|
2 kg |
30 |
100 |
|
300 |
|
1 kg |
16 |
50 |
|
160 |
|
500 g |
8.0 |
25 |
|
80 |
|
200 g |
3.0 |
10 |
|
30 |
|
100 g |
1.6 |
5 |
|
16 |
|
50 g |
1.0 |
3 |
|
10 |
|
20 g |
0.8 |
2.5 |
|
8.0 |
|
10 g |
0.6 |
2.0 |
|
6.0 |
|
5 g |
0.5 |
1.6 |
|
5.0 |
|
2 g |
0.4 |
1.2 |
|
4.0 |
|
1g |
0.3 |
1.0 |
|
3.0 |
|
500 mg |
0.25 |
0.8 |
|
2.5 |
|
200 mg |
0.20 |
0.6 |
|
2.0 |
|
100 mg |
0.16 |
0.5 |
|
1.6 |
|
50 mg |
0.12 |
0.4 |
|
|
|
20 mg |
0.10 |
0.3 |
|
|
|
10 mg |
0.08 |
0.25 |
|
|
|
5 mg |
0.06 |
0.20 |
|
|
|
2 mg |
0.06 |
0.20 |
|
|
|
1 mg |
0.06 |
0.20 |
|
|
|
Table 2: Specifications for weighing equipment for verification and certification of traders' weights
Note:
Column 1 lists the denominations of traders' weights.
The three sub-columns under Column 2 list the best measurement capability weighing equipment must meet for the combined value of discrimination and repeatability tests for each denomination of traders' weight listed in Column 1 for each class of traders’ weight.
Nominal value of traders weights | Best measurement capability on weighing instrument used to test traders’ weights (± mg ) | ||
---|---|---|---|
|
Class M1 |
Class M2 |
Class M3 |
50 kg |
500 |
1500 |
5000 |
20 kg |
200 |
600 |
2000 |
10 kg |
100 |
300 |
1000 |
5 kg |
50 |
150 |
500 |
2 kg |
20 |
60 |
200 |
1 kg |
10 |
30 |
100 |
500 g |
5 |
15 |
50 |
200 g |
2 |
6 |
20 |
100 g |
1 |
3 |
10 |
50 g |
1 |
2 |
6 |
20 g |
1 |
2 |
5 |
10 g |
1 |
1 |
4 |
5 g |
1 |
1 |
3 |
2 g |
1 |
1 |
2 |
1g |
1 |
1 |
2 |
500 mg |
|
1 |
|
200 mg |
|
1 |
|
100 mg |
|
1 |
|
50 mg |
|
|
|
20 mg |
|
|
|
10 mg |
|
|
|
5 mg |
|
|
|
2 mg |
|
|
|
1 mg |
|
|
|
Table 3: Standards of volume - Schedule of maximum permissible errors - Metal contents measures
Nominal value of volume standards | Maximum permissible error (MPE) in excess or deficiency in millilitres (± ml ) working standard |
---|---|
2400 L |
2400 |
2000 L |
2000 |
1000 L |
1000 |
500 L |
500 |
400 L |
400 |
220 L |
110.0 |
200 L |
100.0 |
50 L |
50.0 |
20 L |
20.0 |
10 L |
10.0 |
5 L |
5.0 |
2 L or 1 L |
2.0 |
500 ml |
1.0 |
200 ml |
0.8 |
100 ml |
0.4 |
50 ml |
0.3 |
20 ml |
0.2 |
10 ml, 5 ml |
0.2 |
2 ml or 1 ml |
0.1 |
Table 4: Glass contents and delivery measures - Graduated glass measure
Nominal capacity | Volume equivalent to one subdivision of scale | Maximum permissible error (MPE) |
---|---|---|
5 ml |
0.1 ml |
0.2 ml |
10 ml |
0.2 ml |
0.2 ml |
25 ml |
0.5 ml |
0.25 ml |
50 ml |
1.0 ml |
0.5 ml |
100 ml |
1.0 ml |
0.8 ml |
500 ml |
5.0 ml |
2.0 ml |
1000 ml |
10.0 ml |
4.0 ml |
2000 ml |
20.0 ml |
8.0 ml |
Table 5: Pipettes
Nominal capacity | Maximum permissible error (MPE) ± ml |
---|---|
1 |
0.1 |
2 |
0.1 |
5 |
0.2 |
10 |
0.2 |
25 |
0.2 |
Table 6: Burettes
Nominal capacity | Maximum permissible error (MPE) ± ml |
---|---|
10 millilitres |
0.2 |
25 millilitres |
0.2 |
50 millilitres |
0.3 |
100 millilitres |
0.4 |